FEATURES
BD FACSDiva™ Software provides robust features from setup through analysis
BD FACSDiva v9.0 Software:
Provides powerful index sorting, along with more routine software operation features including overlays, undo/redo, and multiple copying and pasting of all worksheet elements.
BD FACSDiva™ Software v9.0 and greater run on the Microsoft™ Windows™ 10 64-bit operating system. A selected list of BD FACSDiva™ Software features is listed in the following specification table.
The index sorting feature enables laboratories to sort cells into single wells of plates and also easily identify them on plots, in statistics views and in a detailed results file.
Learn more about Qr and Br in BD FACSDiva™ Software, the parameters for characterizing detector performance.
Index sorting
Feature | Specification |
---|---|
Cytometers Supported | BD FACSCanto™ 10-color, BD FACSCelesta™, BD FACSCanto™, BD FACSCanto™ II, BD FACSAria™ II, BD FACSAria™ III, BD FACSAria™ Fusion, BD®LSR II, BD LSRFortessa™ and BD LSRFortessa™ X-20 |
Options Supported | BD FACS™ Loader for the BDFACSCanto™platform, BD®High Throughput Sampler for the BDFACSCanto™and BD®LSR platforms, and BD FACS™Accudropfor the BDFACSAria™platform |
Plates Supported | U, V and flat-bottom 96-well plates, flat-bottom 384-well plates, Terasaki plates (BD FACSAria™ Cytometer only) |
Laser/Filter Support | 145 (See Table 1 inQr and Br in BD FACSDiva™ Software: Parameters for Characterizing Detector Performance) |
Event Display | User-Defined Event Number, User-Defined Percentage |
Standard Gating | Interval, Rectangle, Polygon, Quadrants, Hinged Quadrants |
Logical Gating | And, Or, Not, and Rest Of |
Auto Gating | Auto-Polygon, Auto-Interval, Snap-To Polygon, Snap-To Interval |
Standard Statistics | Minimum, Maximum, Geometric Mean, Mean, Median, Standard Deviation, Percent Coefficient of Variation, Mode |
Robust Statistics | Robust Standard Deviation, Robust Percent Coefficient of Variation |
Analysis Types | Manual or Batch |
Plot Types | Histogram, 2D Dot Plot, 2D Contour Plot, 2D Density Plot |
Plot Alignment Tools | Left, Right, Bottom, Top, Distribute Horizontally, Distribute Vertically |
Performance Tracking Measurements | PMTV, Qr, Br, Bright Bead Target Value, Bright Bead %rCV, Mid Bead Median, Mid Bead %rCV, Dim Bead Median, Dim Bead %rCV, Forward Scatter Laser Delay, Fluorescence Laser Delay, Laser Current, Laser Power, Fluidics Pressure |
Scaling | Linear, Log, Biexponential |
Automated Setup | Define Baseline, Check Performance, Auto Compensation, Reset Target Values |
Export Formats | JPG, TIFF, PNG, BMP, XML, CSV, PDF |
Export Files | Experiments, FCS Files, Statistics, Templates |
Levey-Jennings Plots | Up to 30 |
Operating System | v9.0: Microsoft™ Windows™ 10 |
BD FACSDiva™ Software supports data integrity and helps ensure reproducible results by enabling automated cytometer setup
Experiment and application setup
The software:
- Provides convenient and easy experiment layout tools to simplify creation of experiments
- Enables a graphical view of the entire experiment and allows quick addition of labels, keywords and acquisition attributes to a single tube, multiple tubes, specimens or the entire experiment
- Offers the ability to store experiment, analysis and panel templates for re-use without sacrificing data integrity
- Provides the ability to save specific settings to properly resolve populations of interest with the application settings feature. Once a daily performance check is performed to update settings, application settings can be appliedto ensure that the particular applications with these settings are running consistently from day to day.
Automated Daily Setup and QC
A single daily setup run using BD FACSDiva™ Software and BD FACSDiva™ CS&T Research Beads* supports consistency and accuracy of data acquisition.
Automatic cytometer adjustments
Using the Experiment Layout feature in BD FACSDiva™ Software greatly simplifies and speeds up creating a new experiment.
Key cytometer setup values for PMT voltages, laser delay and area scaling factors are automatically calculated and adjusted to maintain optimal performance levels over time. This automation reduces startup time to approximately five minutes and eliminates multiple error-prone and expensive data acquisitions and calculations.
Note that because of a change in the beads for BD FACSDiva™ Software v7.0 and v8.0, upgrading from BD FACSDiva™ Software v6.x to v8.0 will cause a loss of existing baselines and application settings.
All baselines, performance checks and application settings will have to be recreated, as needed. See theBD FACSDiva Software Reference Manualand theBD Cytometer Setup and Tracking Application Guidefor more details.
Cytometer Configuration Setup
BD FACSDiva™ Software provides a graphic of the cytometer's physical optical configuration, showing the layout of detectors, filters and mirrors. This allows users to select the correct configuration for their work.
Administrators can create specialized configurations for particular applications by dragging filters, mirrors and fluorochromes onto a representation of the optical bench.
Visual tools for cytometer configuration setup
Cytometer configuration setup is quickly completed through drag and drop of parameters, filters or mirrors onto the appropriate optical bench location.
BD FACSDiva™ Software provides automated performance tracking and simplifies quality control
The software automatically tracks a wide range of performance metrics for each detector and laser in the system and displays the results in Levey-Jennings charts.
Alarm criteria can also be set to automatically notify users if performance metrics fall outside these boundaries.
Download Bead Lot Files
BD FACSDiva™ Software enables efficient organization of steps
Efficient and accurate experiment setup
BDFACSDiva™ Software helps users manage experimental details with easy-to-use interfaces and controls.
Acquisition
BD FACSDiva™ Software simplifies data acquisition with a dashboard that provides the tools for immediately viewing acquisition status and for setting acquisition stopping criteria. The application settings feature automatically adjusts voltage settings to daily changes in cytometer performance so that users can run existing applications more simply and quickly.
BD FACSDiva™ Software provides the ability to overlay multiple different samples and any or all populations within each tube of data.
Analysis
BD FACSDiva™ Software provides a wide array of basic analysis features enabling multiple applications to run on the BD FACSCanto™, BD®LSR and BD FACSAria™ Cytometers. These include gating tools to automatically find a population, biexponential scaling to completely see populations that might have negative relative fluorescence intensities, and even overlays to compare multiple tubes or samples.
Reporting
Worksheets are configurable using predefined and customizable headers and footers. Snap-to grids allow for easy alignments of plots, comments and statistics. Previewing and PDF creation can be completed within the BD FACSDiva™ Software interface.
Data management
BD FACSDiva™ Software offers efficient data management tools to simplify data storage as well as improve organization of flow cytometer data. Along with built-in database and database utilities, BD FACSDiva™ Software provides automated data export in a variety of formats including XML, FCS and even ZIP, for multiple files concurrently. Manual export of FCS files creates an experiment folder structure in the operating system for easy identification of data files without the need to open them.
BD FACSDiva™ Software offers simple tools for data reporting that provide flexible defined layout definiton and easy previewing and printing.
Performance
Proactive Performance Monitoring
On a daily basis, BD FACSDiva™ Software automates tracking of all performance metrics, including detection efficiency, standard deviation of electronic noise, laser current and optical background. Viewing these metrics in interactive Levey-Jennings charts, administrators can visually adjust displays and time scales. The software allows notification when performance metrics fall outside specified boundaries for early troubleshooting and correction.
APPLICATIONS
Single-tube setup for common laser and filter combinations
Setting PMT voltages
BD Phosflow™ Monocyte/NK Cell Activation Kit
Eight-color immunophenotyping on BD FACSCanto™ II Cytometer
RESOURCES
Expand AllCollapse All
- Application Notes
- Qr and Br in BD FACSDiva™ Software
- Product Information Sheets
- BD FACSDiva™ Software Installation Guide
- Win 10 Upgrade Instructions
- Product Security Information
- BD FACSDiva™ Flow Cytometry Software
- Job Aids
- BD FACSAria™ Platform Performing Index Sorting
- BD FACSAria Product Family
- BD FACSDiva™ Software v8.0 Administrative Tasks
- BD FACSDiva™ Software v8.0 for BD FACSAria™ Flow Cytometers
- BD FACSCanto Product Family
- BD FACSDiva™ Software v8.0 Administrative Tasks
- BD FACSDiva™ Software v8.0 for BD FACSCanto™ Flow Cytometers
- BD FACSDiva™ Software v8.0 for BD FACSCanto™ Flow Cytometers (with Loader Option)
- BD FACSDiva™ Software v8.0 for BD FACSCanto™ Flow Cytometers (with HTS Option)
- BD FACSLink Interface
- BD FACSLink™ LIS Interface Solution Product Information Sheet
- Quick Reference Guide for creating custom panels in BD FACS™ SPA and BD FACSDiva™ Software for use with the BD FACSLink™ LIS interface
- BD FACSLink™ Quick Reference Guide for using BD FACS™ SPA and BD FACSDiva™ Software with the BD FACSLink™ LIS interface
- BD FACSLink™ Quick Reference Guide for using BD FACSDiva™ Software with the BD FACSLink™ LIS interface
- BD LSRFortessa Product Family
- BD FACSDiva™ Software v8.0 Administrative Tasks
- BD FACSDiva™ Software v8.0 for BD LSRFortessa™ Flow Cytometers
- BD FACSDiva™ Software v8.0 for BD LSRFortessa™ Flow Cytometers (with HTS Option)
- User Guide
- BD® Cytometer Setup and Tracking Application Guide
- Webinars
- Instrument Characterization and Performance Tracking for Digital Flow Cytometers